RLDS-P-L15

Amphenol Advanced Sensors
527-RLDS-P-15
RLDS-P-L15

Tillverk:

Beskrivning:
Nivåstyrenheter Rope Leak Detection System - Non-Positioning Leakage and Wire Break Detection Module with 15M Cable, LET-PLUS Controller, Power Extension Wire, Lead Cable (3M), Testing cable 15M , wire end connector

Livscykel:
Ny produkt:
Nytt från denna tillverkare.
ECAD-modell:
Ladda ned den kostnadsfria Libary Loader för att omvandla denna fil för ditt ECAD-verktyg. Läs mer om ECAD-modellen.

Produktattribut Attributvärde Välj attribut
Amphenol
Produktkategori: Nivåstyrenheter
RoHS-direktivet:  
LET-PLUS
Liquid Level Controller
DIN Rail Mount
LED
120 mm x 85 mm x 55 mm
Märke: Amphenol Advanced Sensors
IP-klassificering: IP65
Maximal drifttemperatur: + 70 C
Minsta drifttemperatur: - 20 C
Antal ingångar: 1 Input
Antal utgångar: 2 Output
Produkttyp: Level Controllers
Underkategori: Controllers
Maximal matningsspänning: 24 VAC, 30 VDC
Minimal matningsspänning: 12 VAC/DC
Termineringsstil: Screw
Handelsnamn: THERMOMETRICS
Hittade produkter:
Markera minst en kryssruta för att visa liknande produkter
Markera minst en kryssruta ovan för att visa liknande produkter i denna kategori.
Attribut som valts: 0

Efterlevnadskoder
USHTS:
8541600050
Ursprungsklassificeringar
Ursprungsland:
Kina
Monteringsland:
Ej tillgänglig
Distributionsland:
Ej tillgänglig
Landet kan komma att ändras vid leveranstillfället.

Läckagedetekteringssensorer med sensorkabel

Amphenol Advanced Sensors Rope Leak Detection Sensors were developed to protect critical equipment and infrastructure. These sensors are a reliable solution for continuous monitoring of liquid leaks across large areas. Designed for use in data centers, industrial facilities, telecommunications rooms, and other mission-critical environments, the sensing rope quickly detects the presence of conductive liquids anywhere along its length. The Amphenol Advanced Sensors Rope Leak Detection Sensors' flexible design allows it to be routed around equipment, under raised floors, and along piping to provide early leak detection, helping prevent costly downtime, equipment damage, and maintenance expenses.

LET-Plus-larmmodul

Amphenol Advanced Sensors LET-Plus Alarm Module adopts standard MODBUS-RTU protocol, standard asynchronous serial two-wire RS485 communication port, and the interval between the host computer reading LET-Plus data is not less than 500ms, and the recommended value is 1s. The Amphenol Advanced Sensors LET-Plus factory default device address is 01; the device address can be changed via a host computer command or LEAK-Talk debugging software, and it supports BACnet IP and Modbus RTU/TCP protocols.

Tillgänglighet

Lager:
0

Du kan fortfarande köpa produkten som en restnoterad beställning.

På beställningen:
10
Förväntad 2026-09-22
Fabrikens ledtid:
6
Veckor Uppskattad tillverkningstid i fabriken för kvantiteter som är större än vad som visas.
Minst: 1   Flera: 1
Enhetspris:
-,-- kr
Ext. pris:
-,-- kr
Est. Pris:
Denna produkt levereras UTAN KOSTNAD

Prissättning (SEK)

Antal Enhetspris
Ext. pris
6 950,30 kr 6 950,30 kr
6 575,65 kr 32 878,25 kr
6 435,85 kr 64 358,50 kr