MCS1805 Linear Hall-Effect Current Sensor ICs

Monolithic Power Systems (MPS) MCS1805 Linear Hall-Effect Current Sensor ICs are designed for AC or DC current sensing. The differential Hall array cancels out any stray magnetic field. The primary conductor’s low resistance allows large currents to flow within close proximity to the integrated circuit, which contains high-accuracy Hall sensors. This current generates a magnetic field sensed at two different points by the integrated Hall transducers. The magnetic field difference between these two points is then converted into a voltage proportional to the applied current. A spinning current technique is used for a low, stable offset.

Resultat: 12
Välj Bild Artikelnummer Tillverk: Beskrivning Datablad Tillgänglighet Prissättning: (SEK) Filtrera resultaten i tabellen efter enhetspris baserat på din kvantitet. Antal RoHS ECAD-modell Märkström Sensortyp Responstid Noggrannhet Frekvensräckvidd Driftspänning Utgångstyp
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD, 3kVRMS Isolation, and 580VRMS Working Voltage
500Förväntad 2026-07-03
Min.: 1
Multipla: 1
Papprulle: 500
5 A Current Sense 4 us 2.5 % 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste
500Förväntad 2026-03-23
Min.: 1
Multipla: 1
Papprulle: 500

50 A Current Sense 4 us 2.5 % 120 kHz 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD, 3kVRMS Isolation, and 580VRMS Working Voltage Ledtid för icke lagerfört 18 Veckor
Min.: 2 500
Multipla: 2 500
Papprulle: 2 500
5 A Current Sense 4 us 2.5 % 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD3kVRMS Isolation, 580VRMS Working Voltage Ledtid för icke lagerfört 18 Veckor
Min.: 2 500
Multipla: 2 500
Papprulle: 2 500

10 A Current Sense 4 us 2.5 % 120 kHz 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD3kVRMS Isolation, 580VRMS Working Voltage Ledtid för icke lagerfört 22 Veckor
Min.: 1
Multipla: 1
Papprulle: 500

10 A Current Sense 4 us 2.5 % 120 kHz 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD, 3kVRMS Isolation, and 580VRMS Working Voltage Ledtid för icke lagerfört 18 Veckor
Min.: 2 500
Multipla: 2 500
Papprulle: 2 500
20 A Current Sense 4 us 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD3kVRMS Isolation, 580VRMS Working Voltage Ledtid för icke lagerfört 22 Veckor
Min.: 1
Multipla: 1
Papprulle: 500

5 A Current Sense 4 us 2.5 % 120 kHz 5 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD3kVRMS Isolation, 580VRMS Working Voltage Ledtid för icke lagerfört 18 Veckor
Min.: 2 500
Multipla: 2 500
Papprulle: 2 500

5 A Current Sense 4 us 2.5 % 120 kHz 5 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD3kVRMS Isolation, 580VRMS Working Voltage Ledtid för icke lagerfört 22 Veckor
Min.: 500
Multipla: 500
Papprulle: 500

50 A Current Sense 4 us 2.5 % 120 kHz 5 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD3kVRMS Isolation, 580VRMS Working Voltage Ledtid för icke lagerfört 18 Veckor
Min.: 2 500
Multipla: 2 500
Papprulle: 2 500

50 A Current Sense 4 us 2.5 % 120 kHz 5 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Linear Hall-Effect Current Sensor with OCD, 3kVRMS Isolation, and 580VRMS Working Voltage Ledtid för icke lagerfört 22 Veckor
Min.: 500
Multipla: 500
Papprulle: 500
20 A Current Sense 4 us 2.5 % 3.3 V Analog
Monolithic Power Systems (MPS) Strömsensorer för kortfäste Ledtid för icke lagerfört 22 Veckor
Min.: 1
Multipla: 1
Papprulle: 500

20 A Current Sense 4 us 2.5 % 120 kHz 5 V Analog