OPT4003DNPRQ1

Texas Instruments
595-OPT4003DNPRQ1
OPT4003DNPRQ1

Tillverk:

Beskrivning:
Omgivande ljussensorer Automotive high-spee d high-precisi

ECAD-modell:
Ladda ned den kostnadsfria Libary Loader för att omvandla denna fil för ditt ECAD-verktyg. Läs mer om ECAD-modellen.

På lager: 1 117

Lager:
1 117 Kan skickas omedelbart
Fabrikens ledtid:
12 Veckor Uppskattad tillverkningstid i fabriken för kvantiteter som är större än vad som visas.
Minst: 1   Flera: 1
Enhetspris:
-,-- kr
Ext. pris:
-,-- kr
Est. Pris:

Prissättning (SEK)

Antal Enhetspris
Ext. pris
18,64 kr 18,64 kr
16,02 kr 160,20 kr
15,37 kr 1.537,00 kr
13,95 kr 6.975,00 kr
13,41 kr 13.410,00 kr
12,64 kr 37.920,00 kr
12,21 kr 73.260,00 kr

Produktattribut Attributvärde Välj attribut
Texas Instruments
Produktkategori: Omgivande ljussensorer
RoHS-direktivet:  
Ambient Light Sensors
USON-6
SMD/SMT
550 nm, 810 nm
1.6 V to 3.6 V
- 40 C
+ 105 C
OPT4003
Märke: Texas Instruments
Falltid: 40 ns, 80 ns, 300 ns
Fuktkänsliga: Yes
Produkttyp: Ambient Light Sensors
Stigtid: 40 ns, 80 ns, 300 ns
Fabriksförpackningskvantitet: 3000
Underkategori: Optical Detectors & Sensors
Typ: Automotive Digital Ambient Light Sensor
Hittade produkter:
Markera minst en kryssruta för att visa liknande produkter
Markera minst en kryssruta ovan för att visa liknande produkter i denna kategori.
Attribut som valts: 0

Denna funktion kräver att Javascript är aktiverat.

CNHTS:
8542391010
CAHTS:
8542390000
USHTS:
8542390090
MXHTS:
8542399999
ECCN:
EAR99

OPT4003-Q1 Digital Ambient Light Sensor

Texas Instruments OPT4003-Q1 Digital Ambient Light Sensor is a dual-channel, light-to-digital sensor (single-chip lux meter and NIR power meter) that independently measures the intensity of visible and near-infrared (NIR) light. A specially engineered filter on the device tightly matches the human eye's photopic response to measure accurate visible light intensity. It rejects the near-infrared component from common light sources. The NIR channel filter is specially engineered to provide high sensitivity to wavelengths in the near-infrared region while achieving high rejection of visible wavelengths with a sharp cutoff at 800nm. The output of the Texas Instruments OPT4003-Q1 is semi-logarithmic with binary logarithmic full-scale light ranges and a highly linear response within each range. The visible channel provides nine binary light ranges, providing measurement capability from 535µlux to 143klux and 28 bits of effective dynamic range. The NIR channel provides seven light ranges, providing measurement capability from 409pW/cm2 to 27mW/cm2 and 26 bits of effective dynamic range. The built-in automatic range selection logic dynamically adjusts the device gain settings based on the light level, providing an excellent resolution in all conditions without user input.